Charger360Vision for station management
Charger360Vision is the hub a charging site's monitoring hangs off. Nodes attach to it over Zigbee and BLE, or through RS485, 1-Wire and 6 digital inputs — panel opening, water at floor level, charger temperature, breaker state. Six relays mean it can act on what it sees: trip the supply, cut off on a sensor, power-cycle a charger.
The charger's own OCPP messages tell you the charger is down. They do not tell you the enclosure is at sixty degrees, the panel door has been open since Tuesday, or there is water under the bay. Those are the things that take an unattended site offline, and they are what this side of the box is for.
The nodes
Each of these is a thing that goes wrong on an unattended site. Several already have a page of their own on riod.energy, linked below.
Charger health
Session outcomes, fault codes and the behaviour of the charger's own contactors, collected over OCPP and the wired I/O rather than inferred from the backend alone.
How charger health is built upPanel monitoring
A door or panel being opened on an unattended site, reported when it happens rather than discovered on the next visit.
Service panel opening monitoringFlood sensing with cut-off
Water detected at floor level, with a relay available to cut the supply rather than only raise an alert.
Charging floor monitoringRemote tripping control
Tripping the supply deliberately, from the platform, without sending somebody to the site to do it by hand.
Remote MCB trip monitoringCharger temperature monitoring
Temperature inside the enclosure, which is the measurement that separates a charger derating in the heat from one that is genuinely faulty.
Remote reset relays
Power-cycling a charger or a subsystem from the platform. The most common fix on a public site is the one that currently needs a van.
Monitoring is cheap. Acting on it is what costs money
Most site monitoring stops at the alert. Something is detected, somebody is notified, and the response is still a person getting into a vehicle. On a site an hour away, the alert has saved nothing except the time it took to find out.
The 6 relays and the 6 digital inputs and outputs are what change that. A breaker can be tripped deliberately from the platform. A charger can be power-cycled without a visit, which resolves a large share of field faults on its own. A water sensor can drive a cut-off directly, without waiting for a round trip to the backend.
That last one deserves a caution rather than a sales line. An automatic cut-off is only as good as the sensor driving it, and a false reading takes a working site down. It is worth deciding deliberately, per site, which conditions act on their own and which raise an alert for a human to judge.
Zigbee and BLE do different jobs
Both radios are in the unit. Which one a node uses depends on where it has to sit.
Zigbee
Mesh for the fixed nodes around the site — panel, floor, temperature — so a sensor across the car park does not need its own cable run back to the charger.
BLE
Short-range devices at the bay itself, including the beacons RIOD uses for cable theft detection.
Read moreWhat you can wire into it
The payment side and the full specification are on the product page.
- Cellular
- Built in
- Wi-Fi
- Built in
- Connectivity mode
- Automatic — the unit selects between Wi-Fi and cellular on its own
- Wireless nodes
- Zigbee and BLE
- Serial
- RS485
- Single wire
- 1-Wire interface
- Relays
- 6
- Digital I/O
- 6 DI / DO
Questions buyers ask
What does station management mean on an EV charging site?
Watching and controlling the things around the charger rather than the charger itself: the supply panel, the temperature in the enclosure, water on the floor, the breaker, and the cable at the bay. These are what take an unattended site down, and none of them appear in the charger's own OCPP messages.
What can Charger360Vision monitor?
Charger health, the supply panel being opened, water at floor level, charger temperature, and the state of the breaker. It can also act: 6 relays and 6 digital inputs and outputs allow remote tripping, remote reset and cutting the supply on a sensor input.
How do the sensors connect?
Zigbee for fixed nodes placed around the site, so a sensor across the car park does not need a cable run back to the charger. BLE for short-range devices at the bay itself. Where a cable already exists, the wired inputs, RS485 or the 1-Wire interface can be used instead.
Can it cut the supply automatically if water is detected?
The hardware supports it: a sensor input can drive a relay without waiting for an instruction from the platform. Whether that is the right behaviour is a site decision, because an automatic cut-off that fires on a false reading takes a working site offline.
Can we reset a charger remotely instead of sending someone?
Yes, that is what the reset relays are for. On a public site the most common fix is a power cycle, and the cost of that fix is almost entirely the van, not the work.
Do I need the payment function to use the station-management side?
No. They are in one box but they are not dependent on each other. A depot that bills nobody can use the monitoring and ignore the UPI display, and a retail site can take payments and add no nodes at all.
Does this replace a BMS or an electrical protection system?
No, and it should not be specified as though it does. Protection devices protect; this watches them and lets you act on what they report. The MCB still trips on its own.
How many nodes can one unit carry?
The wired side is bounded by what is on the unit: 6 relays, 6 digital inputs and outputs, RS485 and 1-Wire. The wireless side depends on the Zigbee mesh and the layout of the site, so it is sized per site rather than quoted as a single number.
The rest of Charger360Vision
Related on riod.energy
Tell us what goes wrong on your sites
The useful version of this conversation starts from the faults you actually get — the ones that need a van — rather than from a list of available sensors. We will work back from there to what is worth fitting.